01 Lead at the abutments
At every point where a slope butts against taller brickwork, lead is dressed up the wall and out over the tiles to shed water. Follow that line with binoculars. Metal that has lifted, split or slumped is a fault, and so is pointing that has dropped out of the joint where the lead is tucked in, because rain gets behind at both. A stain on a bedroom wall beside a chimney or a dormer cheek can trace back to this line rather than to the tiles.
Rolled lead sheet is manufactured to BS EN 12588 in codes 3 to 8, and the specification gives each detail its code. Code 4 is 1.80 mm thick. Weights depend on the maker: code 3 is 14.97 kg/m² on Calder's chart and 15.0 on Ecobat's, so a weight is always quoted with the maker's name. Lead that does not match the code its specification names is worth raising, and a photograph of the lead near a chimney is a good first step. The lead roofing and leadwork page explains what the metal is used for.