01 Escape windows in a loft room
A room made in a roof has to be left in an emergency, and Approved Document B sets out how. For storeys up to 4.5 m above ground, para 2.2 asks for an emergency escape window or direct access to a protected stairway. Para 2.10 gives the window's size: "A minimum area of 0.33m2.", "A minimum height of 450mm and a minimum width of 450mm" and "The bottom of the openable area is a maximum of 1100mm above the floor."
All three conditions apply together. A 450mm by 450mm opening is only about 0.2 m², so the area condition is the one that sets the real size. The window is also a roof job: where it is set into the slope and flush with it, it counts as a roof window, and the Approved Document L figures for a roof window, 1.4 W/m²K or Window Energy Rating Band B minimum, apply to it. Which product is being priced, and which document its figure comes from, is worth asking before a loft room is designed around a window.