01 Eaves courses and the air gap
The lowest courses of a roof sit above the gutter, and they take the run-off from every slope above. From the lane, look at the bottom row of tiles for slips, chips and a lifted edge, and at the board beneath for staining. Inside, the same stretch is where loose insulation can be pushed hard against the roof, closing the gap that lets air move.
For a cold roof under a high-resistance underlay, Marley gives "25mm along the length of the eaves for pitches of 15° or less; 10mm along the length of the eaves for pitches of more than 15°." Under a low-resistance underlay, where the ceiling below is airtight and the tiles above let air pass, Marley says "fortuitous ventilation at the eaves via normal eaves construction (3mm) is all that is required, provided the requirements of UKAS Third Party certification are fully met." Which case an Emberton roof falls into is a matter for the survey, and the air gap has to stay open once the roof is re-covered.