01 A converted loft and its way out
A loft conversion changes what the roof has to do. Under Approved Document B, escape windows serve storeys up to 4.5 m above ground, and where a conversion creates a storey above that height, paragraph 2.5 calls for either a protected stairway or an alternative escape route. Paragraph 2.23 adds a sprinkler option for open-plan layouts. The 2019 edition incorporating 2020, 2022, 2025 and 2026 amendments is the version in use. Insulating the new rooms to the energy rules is a further requirement, covered under Approved Document L.
An escape window must have a minimum area of 0.33m2, a minimum height of 450mm and width of 450mm, and the bottom of its openable area at most 1100mm above the floor. Those details belong to the conversion's designer and building control. A roofer's part is the roof: the structure that carries the new floor, the way the window or dormer is flashed in, and the insulation. See roof replacement. Any new opening in a roof slope has to be flashed in and weathered, and the insulation around it has to be continuous.