01 A loft room and its way out
Approved Document B, in its "2019 edition incorporating 2020, 2022, 2025 and 2026 amendments", ties escape routes to height. An emergency escape window serves a storey up to 4.5 m above ground. For a conversion, the document's words are "Where a new storey is added through conversion to create a storey above 4.5m", and the house then needs either a protected stairway or an alternative escape route, a top storey cut off from the floors below by fire-resisting construction (minimum REI 30) with a final exit of its own. Sprinklers in open-plan areas are a further option under paragraph 2.23.
An escape window itself has minimums: an unobstructed area of 0.33m2, at least 450mm high and 450mm wide, and an openable part whose lowest edge sits 1100mm or less above the floor. A Cottered homeowner planning a loft room is therefore dealing with building control before any rafters are cut, and a roof window that doubles as the escape route has to meet those sizes as well as its energy figures. The skylights and roof windows page explains the units.