01 Underlay and the gap at the eaves
Under the tiles lies a membrane, the underlay, and the type matters for ventilation. Marley's table, for a cold roof carrying underlay of the high-resistance kind, reads "25mm along the length of the eaves for pitches of 15° or less; 10mm along the length of the eaves for pitches of more than 15°". Where the underlay is of the low-resistance kind, the ceiling below is sealed tight and the covering itself lets air through, Marley says "fortuitous ventilation at the eaves via normal eaves construction (3mm) is all that is required, provided the requirements of UKAS Third Party certification are fully met".
High resistance means the sheet stops vapour, so air has to move above it by another route, and that route is the eaves gap. From the hatch, point a torch at the eaves: is the gap open, or has insulation, a stored box or old felt blocked it? BS 5250:2021 covers moisture management in buildings, and it is listed current, under review. The type of underlay a Cuffley roof has is read at the survey, and the choice for a new one is made with the ventilation in mind, so that the gap is built in and not left to chance.