01 Rooflight or roof window
The two are different products, and Approved Document L keeps them apart in its Appendix A, which matters because the heat-loss figure that each must meet is not the same. A rooflight is a glazed unit "out of plane with the surface of the roof on a kerb or upstand", with 2.2 W/m²K as the new-fabric figure. A roof window is "in the same orientation as, and in plane with, the surrounding roof", and its figure is 1.4, or a Window Energy Rating of Band B minimum.
A flush conservation rooflight lies in the slope, so it counts as a roof window; a lantern or a flat-roof dome standing on a kerb counts as a rooflight. The two names cannot be swapped in a heat-loss sentence, and a shop's word for a product may differ from the regulation's. The survey looks at which kind of opening a roof has, because one kind's figure cannot be applied to the other. A photo of the opening from inside and outside, sent on WhatsApp, helps to tell which one it is before anyone climbs up.