01 Minimum pitch, product by product
A roof covering has a lowest pitch it can safely be laid at, and the figure depends on the product. Marley lists its clay Ashdowne tile at 35°, its Hawkins and Acme Single Camber at 30° and its Lincoln pantile at 15°, while its concrete Double Roman sits at 22.5° and its Anglia at 25°. Anglia is a Marley product name and not a place.
Measure the slope with a pitch finder before anyone proposes re-covering in something else, because a covering laid below its minimum lets rain blow up under the laps. Cupa says BS 5534 "indicates that the minimum roof pitch for natural slate is 20 degrees" at moderate exposure with a 500mm slate and a 115mm overlap, adding that "hook fixings should not be used on any pitch below 25º". The survey takes the angle of each slope and sets it against the product. A roof steeper than the minimum has room in hand, while one sitting at the limit has none, so a re-cover in a different covering has to be matched to the slope the rafters give.