The short answer
Yes. Under Class C.2 of the permitted development rights, a roof window set in a side-facing slope has to be obscure-glazed, at any height. It is also non-opening unless the parts that can be opened are more than 1.7 metres above the floor of the room.
The two conditions in Class C.2
Class C permits roof lights and other changes to a house's roof, and paragraph C.2 attaches a condition to them. Any window located on a roof slope forming a side elevation of the dwellinghouse must be "(a) obscure-glazed; and (b) non-opening unless the parts of the window which can be opened are more than 1.7 metres above the floor of the room in which the window is installed".
The two limbs are separate. Obscure glazing is required in every case, with no height at which it stops applying. Only the second limb has a height in it: a unit whose opening parts all lie above that height may open, but it is still obscure-glazed. In its technical guidance, the Government says side windows should be obscure glazed to a minimum of level 3 to count as permitted development.
| Condition | When it applies |
|---|---|
| Obscure-glazed | In every case, at any height |
| Non-opening | Unless every opening part is more than 1.7 m above the floor |
Folding the two limbs into one sentence loses the distinction, because the height test never lifts the glazing requirement. An opening unit above 1.7 metres is still obscure.
Getting this right at the specification stage is simpler than correcting it later, since the glass is part of the sealed unit and cannot be changed without replacing the sash.
Measuring the 1.7 metres properly
The height is taken from the floor of the room in which the window is installed, to the parts of the window that can be opened. In a loft room the ceiling follows the slope, so the lower edge of a roof window may sit well under 1.7 metres even when the unit looks high from the stairs. The measurement that counts is the vertical height of the lowest opening part above the finished floor.
A roof window on a slope descends towards the eaves, so the lower edge of the opening is nearer the floor than the top of the frame. That is why one unit can fail and another, fitted higher up the same slope, can pass. Moving a unit up the slope, or choosing a unit with a different opening arrangement, changes the answer without changing the glass type.
A fixed unit has no opening parts, so the 1.7 metre test does not arise for it. It must still be obscure-glazed. Choosing a fixed unit for a side slope avoids the second limb altogether, at the cost of ventilation and cleaning access, so the balance is a matter for the room.
For a measurement that can be trusted, take it in the room with the floor finish in place, because a new floor build-up lowers the figure a little.
When the conditions do not decide the case
Class C.2 is a condition of permitted development. A side-slope unit that cannot meet it is not automatically ruled out: it would need an application to the council instead. Ask before ordering, so that the council's view on that address is known.
Other limits sit alongside. The roof window must not protrude more than 0.15 metres beyond the plane of the slope of the original roof, and must not rise above the highest part of the original roof. Flats have no householder permitted development rights, a listed house needs listed building consent for work in a manner affecting its special character, and an Article 4 direction can remove further rights. The page on planning permission for a Velux window sets out the general position.
Conservation areas bring their own checks, and roof windows in conservation areas covers them. Send pictures of the side slope and the room under it to WhatsApp on 07880 284133 and they get looked at, and the route is put to the council before anything is ordered. Delays at the planning stage cost less than a unit that has to be taken out again. The skylights and roof windows page lists the surrounding work.