Does a roof window on a side slope need obscure glass?

Glass in a side-slope roof window is obscure in every case. The 1.7 metre figure matters only for the second condition, which is about whether the window is allowed to open.

Get a written quote

Call 01582 935272WhatsApp us

Inside a loft room with a roof window letting in soft daylight
PicturedInside a loft room with a roof window letting in soft daylight.

The short answer

Yes. Under Class C.2 of the permitted development rights, a roof window set in a side-facing slope has to be obscure-glazed, at any height. It is also non-opening unless the parts that can be opened are more than 1.7 metres above the floor of the room.

A roof drawing with its parts named: slates, roof window, lead collarSlatesRoof windowLead collar

The two conditions in Class C.2

Class C permits roof lights and other changes to a house's roof, and paragraph C.2 attaches a condition to them. Any window located on a roof slope forming a side elevation of the dwellinghouse must be "(a) obscure-glazed; and (b) non-opening unless the parts of the window which can be opened are more than 1.7 metres above the floor of the room in which the window is installed".

The two limbs are separate. Obscure glazing is required in every case, with no height at which it stops applying. Only the second limb has a height in it: a unit whose opening parts all lie above that height may open, but it is still obscure-glazed. In its technical guidance, the Government says side windows should be obscure glazed to a minimum of level 3 to count as permitted development.

Class C.2 conditions for a side-slope roof window
ConditionWhen it applies
Obscure-glazedIn every case, at any height
Non-openingUnless every opening part is more than 1.7 m above the floor

Folding the two limbs into one sentence loses the distinction, because the height test never lifts the glazing requirement. An opening unit above 1.7 metres is still obscure.

Getting this right at the specification stage is simpler than correcting it later, since the glass is part of the sealed unit and cannot be changed without replacing the sash.

Measuring the 1.7 metres properly

The height is taken from the floor of the room in which the window is installed, to the parts of the window that can be opened. In a loft room the ceiling follows the slope, so the lower edge of a roof window may sit well under 1.7 metres even when the unit looks high from the stairs. The measurement that counts is the vertical height of the lowest opening part above the finished floor.

A roof window on a slope descends towards the eaves, so the lower edge of the opening is nearer the floor than the top of the frame. That is why one unit can fail and another, fitted higher up the same slope, can pass. Moving a unit up the slope, or choosing a unit with a different opening arrangement, changes the answer without changing the glass type.

A fixed unit has no opening parts, so the 1.7 metre test does not arise for it. It must still be obscure-glazed. Choosing a fixed unit for a side slope avoids the second limb altogether, at the cost of ventilation and cleaning access, so the balance is a matter for the room.

For a measurement that can be trusted, take it in the room with the floor finish in place, because a new floor build-up lowers the figure a little.

When the conditions do not decide the case

Class C.2 is a condition of permitted development. A side-slope unit that cannot meet it is not automatically ruled out: it would need an application to the council instead. Ask before ordering, so that the council's view on that address is known.

Other limits sit alongside. The roof window must not protrude more than 0.15 metres beyond the plane of the slope of the original roof, and must not rise above the highest part of the original roof. Flats have no householder permitted development rights, a listed house needs listed building consent for work in a manner affecting its special character, and an Article 4 direction can remove further rights. The page on planning permission for a Velux window sets out the general position.

Conservation areas bring their own checks, and roof windows in conservation areas covers them. Send pictures of the side slope and the room under it to WhatsApp on 07880 284133 and they get looked at, and the route is put to the council before anything is ordered. Delays at the planning stage cost less than a unit that has to be taken out again. The skylights and roof windows page lists the surrounding work.

Side-slope roof windows, answered

01What counts as obscure glass for a side roof window?

The Government's technical guidance says side windows should be obscure glazed to a minimum of level 3 to be permitted development. The level is the scale of obscurity that glass makers use, and the unit's data sheet states it. A tinted or frosted film applied later does not replace obscure glass built into the pane. The label on the new unit shows the glass specification.

02Does the condition apply to front and rear slopes?

Class C.2 attaches to a window on a roof slope forming a side elevation of the dwellinghouse. A slope that faces the front or the back is not covered by that wording, though the 0.15 metre and height limits still apply to every Class C alteration. If you are unsure which slope counts as the side, ask the council. A short call to the council settles it.

03Can a side-slope roof window open at all?

Yes, but only if the parts that can be opened are more than 1.7 metres above the floor of the room in which the window is installed. Below that height the unit has to be non-opening, meaning fixed shut. In both cases the glass has to be obscure-glazed, so opening above 1.7 metres does not remove that requirement. Measure from the finished floor.

04What happens if the unit cannot meet the conditions?

It falls outside permitted development under Class C and would need planning permission from the council. Whether permission would be given is the council's decision. Raise it before the unit is ordered, with a picture of the slope and the intended position, so that the choice of unit or its height can change at the planning stage. A second option is a different unit.