The short answer
Velux is a roof window brand, so every Velux window is a roof window, but not every roof window is a Velux. Approved Document L sorts a window set flush into a slope as a roof window and asks 1.4 or Window Energy Rating Band B minimum of it, whoever made it.
A brand name and a product name
A roof window is a window made to be fitted into a pitched roof, flush with the slope, so that it lets light and a view into the room beneath. Velux is one manufacturer of such windows, and its name has become a shorthand for the whole product, in the way that some vacuum cleaners are called by a brand. In ordinary conversation the two words end up meaning the same thing.
In a quote or a specification they should not. A line that says Velux names a maker and, through the model code, a particular size and specification. A line that says roof window names the kind of unit. When you ask for a price to replace one, it helps to give both: the model if you know it, and the plain description if you do not. The model number can be found on a label on the frame, and a photo of the window sent to WhatsApp on 07880 284133 can be looked at.
Other manufacturers sell roof windows too, and a unit from another maker is still a roof window in every regulatory sense. Choosing between makers is a matter of fit with the existing opening, the covering around it, the rating and the price. It is not a question the building rules answer.
What the building rules actually name
Approved Document L sorts windows in a roof by their position and never refers to a brand. Its Appendix A says a roof window is "A window installed in the same orientation as, and in plane with, the surrounding roof." A rooflight, by the same appendix, is "A glazed unit installed out of plane with the surface of the roof on a kerb or upstand." A Velux or any other maker's window set into a slope meets the first definition, so it is a roof window.
The figures that go with the name are the point. In Table 4.2 of the 2021 edition, a rooflight is given 2.2, and the row for a roof window reads 1.4 or Window Energy Rating Band B minimum. The table has no column for makers. What decides whether a unit passes is the rating on its own data sheet, not the name on its frame.
| Word on the quote | What it tells you |
|---|---|
| Velux | The maker, and with the model code the size and specification |
| Roof window | The kind of unit, with its Part L row of 1.4 or Band B minimum |
| Rooflight | A unit raised on a kerb, with a 2.2 figure |
No brand carries an automatic pass. Approval of any kind is not something a maker's name confers, so check the rating of the unit that is actually quoted.
What this means when you replace one
A like-for-like swap keeps the opening, but the new unit still has to reach the Table 4.2 figure for a roof window, and the flashing kit that goes with it has to suit both the unit and the covering. If you change to another maker, the frame size and the kit change with it, and the survey checks that the new unit fits the opening and the surrounding tiles or slates.
Planning follows the product, not the brand. Roof windows in a house roof come under Class C of the householder permitted development rights. Obscure glazing is a condition for any window on a side slope, and flats have no householder permitted development rights. If the house is listed, any work that would "affect its character as a building of special architectural or historic interest" needs listed building consent. An Article 4 direction can also remove rights in a given area, so we check with the council first.