01 Dormer cheeks and flat tops
Where a window projects from a pitched roof, it sits in a dormer: two cheeks, a face and a flat or shallow top. Each of those three parts can fail on its own. Look at the cheeks for slipped tiles, cracked lead or paint peeling in a streak; look at the top for ponding, a lifted edge or a gutter that has pulled away; look at the window frame for damp at its corners. Inside, a stain at the corner of the dormer ceiling gives the game away.
The top of a dormer can be a small flat roof, and BS 6229:2025 is the current code for continuously supported flexible coverings. NFRC reports that it sets "a minimum 1:80 finished fall for general roof areas and internal gutters", and IKO's reading is that the code means designing for 1:40 so as to reach it. Which? price EPDM with new boards at £1,950 to £4,000 for a single garage of 6m by 3m (November 2025, excluding VAT), a size well beyond a dormer top, so a dormer is priced from its own survey. Check also that the cheeks meet the main slope in a neat lead soaker line, since that junction is where cheek and slope meet and a flashing has to seal the join.