01 Pooling on a flat roof
Look at a flat roof an hour after rain. Standing water that has not cleared, a dull ring where a puddle dried, or a surface that has gone brittle at the edges all show where the fall is wrong. NFRC's key points on BS 6229:2025 call for "a minimum 1:80 finished fall for general roof areas and internal gutters", and IKO reports 1:40 as the figure the code says to design for. On a sunny day, a quick walk round the outside with the camera is worth more than a guess from the kitchen window. A bucket test works too: place a straight edge across the roof and look for gaps beneath it.
BS 6229:2025 covers continuously supported flexible membranes, not lead. A roof that holds water is not always leaking yet, but a ponded area is where a membrane can wear sooner, and dealing with it before it fails keeps the repair smaller. A photograph taken from a bedroom window above is enough to start the conversation. Ponding also adds weight to the roof structure, which is one more reason to deal with it.