The short answer
A commercial flat roof can be insulated as a warm roof: rigid boards go above the deck, a vapour control layer sits on the warm side and the waterproof membrane covers them. The build-up keeps the deck warm and manages condensation, and the falls to the outlets are set again once the thickness is known.
Warm roof or cold roof, and why the choice matters
On a flat roof, the insulation can go above the structural deck or below it. Above the deck is a warm roof. The deck, the steel and the timber under it sit on the heated side of the insulation, so they stay close to room temperature. Below the deck, with an air space left above the insulation, is a cold roof, and that space has to be ventilated or moisture collects in it.
Moisture is the reason the build-up matters. Warm, damp air from inside a building can pass into the roof and condense where it meets a cold surface. The standard behind this work is BS 5250, which BSI lists as current, though under review, and which deals with how moisture behaves inside buildings. A vapour control layer laid below the boards holds the air back, and a warm roof keeps the dew point inside the insulation, where it does less harm than inside a cold deck.
Ventilation figures such as the ones Marley gives for a pitched cold roof do not transfer to a flat roof, so a cold flat roof is designed on its own terms by whoever specifies it. Where a roof is already cold, the existing air space and its ventilation are checked before anything is added, because insulation pushed into a ventilated void can block the airflow the roof depends on.
The layers of a warm roof and what each one does
A warm roof is a stack of layers, and each has a job. The table runs from the underside up, and a fault in any one of them shows up later as damp, sagging or a cold interior. Order is fixed: a membrane laid over damp boards seals the damp in and cannot dry it out.
| Layer | Job |
|---|---|
| Structural deck | Carries the whole roof |
| Vapour control layer | Stops warm air reaching the insulation |
| Insulation boards | Holds heat inside |
| Waterproof membrane | Sheds rain to the outlets |
Falls come into it as well. NFRC reports that BS 6229:2025 sets a minimum 1:80 finished fall for general roof areas and internal gutters; IKO reports that the code puts the design figure at 1:40. Tapered insulation boards are one way of building those falls into a roof whose deck is flat, since the boards themselves slope towards the outlets. The finished falls are worth checking once the insulation is down, and before the membrane goes over it, because a correction is far easier at that stage.
Energy rules and working on site
Energy performance is regulated, and the numbers depend on the building. Approved Document L Volume 1 covers dwellings, so its U-values are not a guide for a shop, a factory or a warehouse. Ask building control, which is the council's team or a registered building control approver, what applies to your premises and whether the work counts as a renovation of the roof.
Insulation has to stay dry. Boards left out in rain or laid over a wet deck carry that moisture into the build-up, where the membrane then seals it in. Boards need covering or protecting before rain reaches them for that reason, and a damp or frosty deck is a reason to hold the work. Makers also set temperature limits for adhesives and membranes, which is why winter flat roofing is planned around the weather.
A thicker roof also changes the details at the edges. Upstands, thresholds, rooflight kerbs and outlets all sit at a new height, and the roof survey checks each of them before one written price is set. The commercial roofing page lists the work, and the guide to single-ply membranes for commercial roofs covers the waterproofing layer that goes over the boards.