Flat roofing

Warm and cold flat roofs: insulation and condensation

A flat roof is a warm roof or a cold roof according to where its insulation sits, and that one choice decides where condensation can form. A cold roof also needs ventilation, and renewing either kind can bring the energy rules into play.

9 minute read

Get a written quote

Call 01582 935272WhatsApp us

New breathable membrane and battens on a roof ready for tiling
PicturedNew breathable membrane and battens on a roof ready for tiling.
A roof drawing with its parts named: lantern, rubber deck, outlet, lead flashingLanternRubber deckOutletLead flashing

Where the insulation sits names the roof

Every flat roof has the same basic layers: a structural deck, insulation to hold heat in, a ceiling below and a waterproof covering above. What changes between a warm roof and a cold roof is the position of the insulation in relation to the deck, and that position decides how the roof behaves when warm, damp air from inside the building reaches it.

In a warm roof the insulation sits above the deck, directly under the waterproof covering. The deck and the joists stay on the warm side of the insulation, close to room temperature. In a cold roof the insulation sits below the deck, between the joists or on the ceiling, leaving the deck and the void above the insulation on the cold side.

Warm and cold roofs compared
FeatureWarm roofCold roof
InsulationAbove the deckBelow the deck
Deck and joistsKept warmLeft cold
VoidNone to ventilateVentilated
Vapour control layerUnder the insulationAt the ceiling

The flat roofing section covers the coverings that go on top of either build. The covering is chosen separately from the insulation position, though the two are specified together on a replacement, because each puts its own demands on the other: a covering that is bonded down needs a firm surface of insulation board, and a loose-laid one needs a deck that will hold fixings.

How condensation forms in a roof

Air indoors carries water vapour from breathing, cooking, washing and drying clothes. Warm air holds more vapour than cold air, so when warm air meets a cold surface it can no longer hold all of its moisture, and the excess turns to liquid. That is condensation, and in a roof it can form on the underside of a cold deck or inside the insulation where the temperature drops below the point at which the vapour condenses.

Damp that builds up this way is hard to see, because it forms inside the roof. Signs are ceiling stains, dark patches, damp insulation, soft timber and, under the deck, mould or droplets. A sound covering can still sit over wet timber.

What the household does inside matters too. Extractor fans in kitchens and bathrooms, ventilated tumble dryers and a habit of keeping a lid on pans all cut the vapour that reaches the ceiling, and damp patches on the ceiling above a bathroom are worth reporting at the survey. Two defences work together. A vapour control layer slows the passage of moist air up into the roof from the room below. And the layers above it are arranged, or ventilated, so that any moisture which does reach them can escape without finding a cold surface to settle on. A warm roof leans on the first defence, plus an insulation position that keeps the deck warm. A cold roof relies on both, with ventilation as the second line.

BSI lists BS 5250:2021, its code of practice on moisture in buildings, as current but under review. A surveyor weighing a roof's build-up reads it against what is found in the layers, and a damp reading in one place does not condemn the roof elsewhere.

What a cold roof needs

In a cold roof, moisture leaves by air passing through the void above the insulation. Openings at opposite edges of the roof let air pass across, and nothing in the void may block that route: not a deep layer of insulation pushed up against the deck, not a blocked soffit vent, not a fascia detail that has been boxed in during a refit.

Marley's figures cover a pitched cold roof under tiles, where the underlay is high-resistance: 25 mm along the eaves for pitches of 15° or less, and 10 mm for steeper ones. The figures belong to that build and its pitch, and they are not a flat roof rule. A flat cold roof has its own ventilation requirement, which the designer works out from BS 5250 for the roof in question.

  • openings at opposite edges so air crosses the void
  • a clear gap between the insulation and the underside of the deck
  • a vapour control layer at the ceiling that is sealed at its edges and around any light fitting or pipe
  • no boxing-in of the eaves during later work

Problems arise when a cold roof has been altered. A previous owner may have added insulation or boxed in the eaves without any record. Loft insulation added over the years, or a new ceiling with downlights cut into it, can break the vapour control layer, while insulation packed against the deck can close the ventilation gap. A survey of a cold roof that has been renovated before looks at what lies in the void as well as at the covering.

How a warm roof is built

A warm roof starts with the deck. A vapour control layer goes onto it, then rigid insulation boards go over that, and the waterproof covering sits on top of the insulation. Because the insulation is outside the structure, the deck and joists stay near room temperature and the dew point falls within the insulation layer or above it, where no timber can be damaged.

There is no void to ventilate. That is one reason to specify a warm roof where the shape is complicated, with rooflights, upstands and changes of level, since no air path has to be kept clear through the awkward corners. The covering is bonded or fixed to the insulation, so the insulation boards have to be rated for that use and fixed in the way the covering manufacturer requires.

The build-up has a height, and height creates detail problems. A warm roof is thicker than a cold roof with the same insulation value, so thresholds, door sills, upstands at walls and window cills need checking before the roof is raised. At the wall, flashings may have to be re-formed at the higher level.

A warm roof can be laid over an existing deck without lifting it, if the deck is sound and dry, which keeps the disturbance to the rooms below to a minimum. The survey establishes that, and any damp timber is dealt with before anything is laid on it, since a vapour control layer will seal moisture in as well as keep it out. A moisture reading taken at several points across the deck, and a look at the edges where the deck meets the walls, tell the surveyor whether the existing boards can stay.

Part L and a renewed flat roof

Insulation is not optional when a flat roof is renewed. Under Approved Document L, a re-covered flat roof sits among the renovation cases. Past the 50% mark on the roof's area, the roof is meant to reach Table 4.3's improved 0.16 W/m²K against a 0.35 threshold, so far as that proves feasible. Para 4.13 allows a lower standard where the full upgrade is not feasible or would not pay back within 15 years.

On an existing flat roof, this can change the build. A cold roof renewed to the improved standard may need so much insulation between the joists that the ventilation gap is lost, and the answer can be to convert it to a warm roof, with new insulation above the deck. A roof that is already warm may need boards added or replaced, and the details at the edges raised to suit.

The flat roof Building Regulations guide sets out the renovation rule and the other tests that apply. AD L 2026 takes effect on 24 March 2027, with its tables renumbered, and until then the 2021 edition applies in England.

The roof insulation question is also a question for the building control route, which we check with the council before work starts. A quote that gives the board type and thickness lets the U-value the roof will reach be checked against the standard.

Insulation, VAT and what to ask a quote

HMRC's Notice 708/6 covers energy-saving materials. Its rule on insulation names roofs or lofts: installations made between 1 May 2023 and 31 March 2027 are zero-rated, and then the reduced rate of 5% applies. Whether your own roof job falls under it depends on what is supplied and installed, so confirm the VAT treatment with the supplier or with HMRC.

Our quote is one written total, with the insulation counted as part of the roof work it prices, whichever build-up is chosen. What you can usefully ask of any quote, ours or another firm's, is for the build-up to be named: warm or cold, the insulation material, its thickness, the vapour control layer and the covering. Those are the details that decide how the roof behaves.

  • warm roof or cold roof, stated in the quote
  • the insulation material and its thickness
  • where the vapour control layer sits
  • how a cold roof will be ventilated, if one is kept
  • what happens at thresholds, upstands and rooflight kerbs

A look at the roof starts with a survey, after which you are told what the roof showed and anything else it showed. To get one moving, call 01582 935272 or send a photograph of the ceiling stains to WhatsApp on 07880 284133. The page on flat roofs in winter covers what cold weather does to the roof and the work.

Warm roof or cold roof: questions about insulation

01What is the difference between a warm roof and a cold roof?

It is the position of the insulation. In a warm roof it sits above the deck, under the waterproof covering, so the deck stays warm, and moisture has no cold surface to settle on. In a cold roof it sits below the deck, between the joists, and the void above it is ventilated. The position decides where condensation can form, and which defences the roof needs against it, so the survey identifies the build before any cost is set.

02Why does a flat roof get condensation inside it?

Warm, damp air from the room reaches a cold surface, such as the underside of a cold deck, and the moisture turns to liquid. A vapour control layer slows the air's passage into the roof, and a cold roof also needs ventilation across the void. A damaged vapour layer, a gap around a light fitting or a blocked vent lets moisture collect where it cannot escape, and the stain on the ceiling appears later.

03How much ventilation does a cold roof need?

Marley gives 25 mm along the eaves for pitches of 15° or less and 10 mm above 15°, for a cold pitched roof with high-resistance underlay. That is not a flat roof figure, so it should not be quoted back to you as one. A flat cold roof has openings sized to BS 5250 by whoever designs it, and the survey checks that they are clear and that the insulation has not closed the gap.

04Does renewing a flat roof mean adding insulation?

It can. AD L places a new waterproof membrane among its renovation cases, and once the work reaches more than 50% of the roof, the target is 0.16 W/m²K against a 0.35 threshold, where that is feasible. If the full figure cannot be reached, or would take longer than 15 years to repay, the target is lowered. You are told plainly what is proposed and why.

05Is roof insulation zero-rated for VAT?

HMRC's Notice 708/6 lists insulation in roofs or lofts among energy-saving materials that are zero-rated when installed between 1 May 2023 and 31 March 2027, then at the reduced rate of 5%. Whether a given roof job qualifies depends on what is supplied and installed, so check with the supplier or HMRC. Roof repairs fall outside what that notice settles.