Call 01582 935272

Flat roofing

What is the minimum fall for a flat roof?

Flat roofs are built with a gentle slope so that rainwater drains off. The figure that matters is a ratio, and two different ratios appear in the guidance.

Get a written quote

Call 01582 935272WhatsApp us

A new grey GRP fibreglass flat roof on an extension in bright sun
PicturedA new grey GRP fibreglass flat roof on an extension in bright sun.

The short answer

The minimum finished fall for a membrane flat roof is 1:80, according to NFRC's summary of BS 6229:2025, which gives it for general roof areas and internal gutters. Because 1:80 has to be achieved on the finished roof, IKO states that 1:40 is the fall to design for. The standard covers membranes, not lead.

A roof drawing with its parts named: lantern, rubber deck, outlet, lead flashingLanternRubber deckOutletLead flashing

How to read a 1:80 fall

A fall is a slope written as a ratio. The first number is the drop and the second is the distance it happens over, so 1:80 means one unit of drop for every 80 units along the roof. In millimetres, that is 12.5 mm of drop for each metre. Across a 4 m run the roof falls by 50 mm, and the slope itself is well under one degree, so a flat roof still looks flat from the garden. The ratio belongs to the roof surface itself, measured between the highest point and the outlet it drains to.

That is the figure for the finished roof, as built. The ratio 1:40 is twice as steep, at 25 mm of drop per metre. A roof laid to 1:40 on the drawings has room to lose some of that on site and still finish at or above 1:80. The table sets the two side by side.

The two ratios in the guidance
RatioDrop per metreWhere it appears
1:8012.5 mmMinimum finished fall
1:4025 mmDesign fall for 1:80

Where BS 6229 sets the number

BS 6229:2025 is the current British Standard for flat roofs with continuously supported flexible waterproof coverings, published on 16 December 2025. It replaces the 2018 edition, which BSI lists as withdrawn. Its scope is curved roofs with a pitch not greater than 10 degrees as well as flat ones, and it deals with EPDM, GRP and felt membranes. Lead sheet is outside it. A lead roof is detailed to its own specification instead.

NFRC, the roofing federation, summarises the standard for its members and reports "a minimum 1:80 finished fall for general roof areas and internal gutters". IKO, a membrane manufacturer, writes: "To achieve a 1:80 fall, the code of practice says that the roof should be designed for a fall of 1:40". The two statements describe different stages: what the finished roof must reach and what the design aims for.

A roof called flat in a quote is still built with a slope. The flat roof building regulations guide covers the approval side of renewing one, and the flat roofing section sets out the coverings that follow the standard. Fall is part of what a flat roof survey looks at.

Checking the fall on your own roof

After a spell of rain, look at where water lies. A wet patch that stays when the remainder of the roof has dried points to a low spot, or to too little slope. A roof with no fall at all holds a film of water across the whole surface, and the membrane is then working while submerged. Describe what you can see from a window and send a photo, and a survey will do the measuring.

A survey measures rather than guesses. A level and a long straightedge show the slope between the outlet and the highest point, and a dip in the deck shows up as a gap under the straightedge. Where a fall is short, a new one can be built into a recovered roof with tapered insulation boards or timber firrings laid on the deck, depending on the structure and the build-up. Because the standard speaks of the finished fall, new layers laid on a roof can change the slope, so a quote for a recovered roof is worth reading with that in mind.

The EPDM roof and GRP roof answers describe two coverings that depend on a fall. Standing water can shorten the working life of any of them, so an outlet that is blocked with leaves is worth clearing, and any dip that keeps holding water is worth raising at the survey.

Fall questions, answered plainly

01Can a flat roof be completely level?

Not if it follows BS 6229:2025. NFRC reports that the standard sets a minimum 1:80 finished fall for general roof areas and internal gutters. Water then has somewhere to go. A roof laid dead level will hold a film of water across its surface, and a membrane in that position is working harder than its maker intended. A fall is part of the design, not an extra.

02Does the 1:80 figure apply to a lead flat roof?

No. BS 6229:2025 covers continuously supported flexible waterproof coverings, which means EPDM, GRP and felt membranes, and it does not cover lead. A lead roof is detailed to its own specification, with falls set by that design. Say which covering a quote is for, so that the right guidance is used. Mixing the two up leads to the wrong specification.

03How is a fall added to a roof that has none?

When a roof is stripped and recovered, a fall can be built in with tapered insulation boards or timber firrings. The method depends on the deck, the edge heights and the doors, so the survey measures them first. Insulation position affects that choice, and a roof with little edge height has less room for added thickness. Neither is a quick fix.

04Is 1:80 the same as a slope of one degree?

No. A slope of one degree rises about 17 mm over a metre, while 1:80 is 12.5 mm over a metre, so 1:80 is less steep than one degree. This is why a flat roof looks flat even when it is built to the standard. The ratio is the figure to quote, not an angle. Fall is checked on the finished surface.

Get a written price for your roof

10-year workmanship guarantee, in writing

Tell us about your roof

Call WhatsApp Written quote