Call 01582 935272

Flat roofing

Is lead still used on flat roofs?

Rolled lead sheet is still made and can cover a flat roof, though it is a different system from rubber, GRP or felt. Lifespans, codes and the standards that apply are set out below.

Get a written quote

Call 01582 935272WhatsApp us

A valley between two concrete tile slopes with a dry valley trough
PicturedA valley between two concrete tile slopes with a dry valley trough.

The short answer

Yes. Rolled lead sheet is still made to BS EN 12588 and can cover a flat roof, as well as forming flashings, with HomeBuilding giving lead flat roofs 60-100 years and Less 50 to 100. BS 6229:2025 does not cover lead, because it deals with membranes.

A roof drawing with its parts named: lantern, rubber deck, outlet, lead flashingLanternRubber deckOutletLead flashing

Where lead still appears on flat roofs

Lead is a metal covering, laid as rolled sheet in separate bays, not as a single membrane. It is still made and sold for roofing, to the standard BS EN 12588. On a flat roof it can form the whole covering of a small area, such as a bay window roof or a porch, and it can make the flashings and upstands that seal a flat roof against a wall.

A flat roof covered in lead is built differently from one with a membrane. The sheets are joined by rolls over timber battens or by welted seams, and each bay is limited in size so that the metal can move as it warms and cools. That movement is why lead goes down in smaller pieces, and each joint has to be formed with care so the metal can slide without splitting.

Lead is also a choice made for a reason. It suits roofs with awkward shapes, since it can be dressed to a form, and it suits buildings where a metal covering is expected. For an ordinary garage or extension roof, a membrane is the comparison that comes up, and the guide on EPDM, GRP and felt sets out those three coverings.

How long lead can last

Published lifespans for lead on a flat roof are long, but HomeBuilding and Less give different ranges. Each range is shown in the table with its own source, and neither is a promise for any individual roof. Lead has the longest range on both writers' lists, ahead of the membrane coverings, whose spans they give as shorter.

Published lifespans for lead on flat roofs
SourceLead flat roof
HomeBuilding60-100 years
Less"Longest-lasting option at 50 to 100 years"

A separate figure belongs to flashings. MyJobQuote says that correctly installed lead flashing can last for over 80 years, and that is a statement about flashing, not about a whole lead roof. The maker VMZinc says a zinc roof, correctly designed and installed, can last in excess of 100 years, which is another metal and another system.

What a given lead roof achieves rests on the standard of its installation, the code of sheet chosen and the detailing at each joint and edge, and that is why no range can be read as a forecast. The page on how long a flat roof lasts sets lead beside the other coverings.

Codes, standards and what BS 6229 leaves out

Lead sheet comes in codes 3 to 8 under BS EN 12588, and each code is tied to one thickness of sheet. Code 4, for instance, measures 1.80 mm, and both the Calder and Ecobat weight charts list 20.41 kg/m² for it. Which code goes where is a specification decision made for each detail, so the lining of a gutter, a wall flashing and a roof bay may each be given a different code, depending on the movement and the load each has to take.

BS 6229:2025 is the current flat roof code, but its scope is flat roofs with continuously supported flexible waterproof coverings, which means membranes. Lead is a metal sheet and sits outside that scope. A lead flat roof is therefore specified from the lead sheet standard and the manufacturer's guidance, with falls and drainage worked out for the job in hand.

A lead roof still needs working falls and outlets, like any other flat roof, and the survey is where those are checked. The flat roofing page lists the coverings used on flat roofs. Photographs of an existing lead roof or flashing sent to WhatsApp on 07880 284133 give a first idea of its condition. Where work is needed, you receive a written price after the survey, as one sum for the whole job.

Lead on flat roofs, answered

01What does a lead code number mean?

A code is the number that names the thickness of rolled lead sheet made to BS EN 12588, from code 3 to code 8. Code 4 is 1.80 mm thick. Weights are quoted by maker, because Calder and Ecobat give different figures for codes 3 and 6, and the same 20.41 kg/m² for code 4. Each part of a roof gets its code from the specification.

02Can lead sit on the same roof as a rubber or felt membrane?

It can. Lead flashings and upstands can finish the edges of a flat roof while the main area carries a membrane. The join between the two materials needs careful detailing so that water is shed over it and not behind it, and the membrane maker's instructions may set limits on what touches it. Which combination suits a roof is a matter for the survey.

03Is zinc an alternative to lead on a flat roof?

It is another metal covering. The maker VMZinc says a zinc roof "can last in excess of 100 years" if it is correctly designed and installed. That statement is the manufacturer's own about its product, not a forecast for any roof. Metal roofs are specified differently from membranes, so whether zinc or lead suits a given building depends on its shape and detail.

04What does lead look like when it is on a roof?

Weathered lead is a dull grey metal, soft enough to dent, and where it covers an area it is laid in bays with raised rolls or folded seams. A flashing against a wall may be lead even where the main roof is something else. Send a photograph to WhatsApp on 07880 284133, or ring 01582 935272 with questions about what you see.

Get a written price for your roof

10-year workmanship guarantee, in writing

Tell us about your roof

Call WhatsApp Written quote