What is an upstand on a flat roof?

An upstand is where a flat roof's covering climbs a wall or kerb. It is a short strip of membrane, yet it is a detail where leaks can start.

Get a written quote

Call 01582 935272WhatsApp us

Kitchen-diner lit by a large flat rooflight in the ceiling
PicturedKitchen-diner lit by a large flat rooflight in the ceiling.

The short answer

An upstand is the part of a flat roof where the waterproof covering turns upward to meet a wall, a parapet, a rooflight kerb or a pipe. The turned-up edge keeps water from running behind the covering, and a flashing or capping fixed over its top edge shields it from rain running down the wall.

A roof drawing with its parts named: lantern, rubber deck, outlet, lead flashingLanternRubber deckOutletLead flashing

Where an upstand turns up

A flat roof is a shallow tray, and the upstand is its rim. Wherever the roof stops at something vertical, the membrane does not stop with it. It carries on upward for a short height, so that water lying on the roof has to climb the turn-up before it can reach the join with the wall. This is one of the details that sets a lasting flat roof apart from a leaking one.

You will find upstands at the wall of a house where an extension roof abuts it, along a parapet, around a pipe or vent that pierces the roof, and at the door threshold of a balcony or roof terrace. Rooflights make the idea concrete. In Approved Document L the word rooflight means glazing "out of plane with the surface of the roof on a kerb or upstand", so the kerb beneath a lantern or dome is itself an upstand, with the membrane wrapped up and over it.

The turned-up membrane is the waterproofing, but it is not left exposed at the top. A flashing, a capping or the wall's own coursing is fixed over the top edge, to shed the rain that runs down the wall so it cannot get behind the membrane. The upstand and the flashing work as a pair, and the pair is only as sound as the join between them.

What fails at the turn-up

An upstand has more to cope with than the open roof. The membrane has to bend through a right angle, the wall behind it moves slightly at a different rate from the roof, and the top edge is exposed to rain running down the wall. Each of those can wear the detail.

Corners take the most folding of any part, so a split at an internal corner is a place to look. Where the membrane has peeled off the brickwork, water has a gap to enter by. A flashing that has lifted, cracked or lost its seal lets rain run behind the turn-up, and moss or leaf litter packed into the angle can hold water against it. Leaf litter and moss in the angle are easy to see from a window and can be cleared before they cause harm.

Junction signs read together
SignPossible cause
Membrane lifting off the wallBond or fixing has let go
Split at a cornerFolding has fatigued the sheet
Gap under the flashingRain can run behind the turn-up
Stain on the ceiling by the wallWater entering at the junction

The flat roof problems guide places the upstand among the other faults a flat roof can develop.

Checking an upstand before it leaks

Walk round the house and look along every wall the roof meets. You are looking for a membrane that stands flat and tight to the brickwork, a flashing that sits snug over its top, and no gap, bulge or stain between them. Indoors, check the line where the ceiling meets that same wall after heavy rain, because a leak at the junction can mark the paint there.

A survey goes further. It reads how the membrane is fixed at the turn-up, how far it climbs, how the flashing laps over it and whether the deck behind is sound. How the detail is formed depends on the covering: a sheet of EPDM is folded and bonded up the wall, GRP is laid wet into the corner, and felt is dressed up in layers. A detail that suits one is not copied onto another.

A faulty upstand does not always mean a new roof. When the field of the roof and its deck are in good order, the turn-up can sometimes be remade on its own. The repair or replace guide weighs the two options. We can also look at a photo of the junction if you send one on WhatsApp.

Upstand questions, answered plainly

01How high should an upstand be?

The height is set by the specification for the roof and by the maker of the covering, and no single figure fits every roof. A roof that floods in heavy rain, or one that sits below a tall wall, calls for different treatment from a sheltered roof. The survey measures what is actually there and tells you plainly what it finds.

02Is an upstand the same thing as a flashing?

No. The upstand is the waterproof covering itself, turned up the wall or kerb. The flashing is the separate strip of metal or other material fixed over the top edge to shed rain from the wall. A junction needs both parts, and either one can fail while the other still looks sound from the ground. Check both when you read a quote, and ask where the flashing is fixed.

03Can one upstand be repaired without redoing the roof?

It can be, when the deck underneath is firm and the main area of the membrane is in good order. The old turn-up is trimmed back to sound material and a new one is formed with a fresh flashing. Where the membrane has worn right across the roof, mending one edge only delays a wider job, and the survey shows which case applies.

04Why is there damp on an inner wall beside the flat roof?

The junction between roof and wall is one possible source, and a failed upstand or flashing there can let water run into the structure. Other causes exist, including condensation, a blocked outlet or a leak further along the roof. A photo of the mark inside, taken next to one of the roof edge from outside, helps narrow it down. A survey then tests each possibility in turn.

Get a written price for your roof

10-year workmanship guarantee, in writing

Tell us about your roof

Call WhatsApp Written quote