What a lead bay roof is
A bay window pushes out from the wall of a house, and the small roof above it has to join the main wall on one side and shed water on the other three. The covering can be tiles or slates where the pitch allows, but some bays are roofed in lead, because a sheet of lead can be shaped to the angles of a bay and dressed into every corner without a join that cannot be sealed. A porch roof works on the same principle, on a smaller scale.
From a distance a bay roof looks like a simple cap. Close up it is a set of separate details. There is a top surface, which may be flat or may slope gently back towards the wall. There are the two angled sides of the bay, the front edge that overhangs the window, and the abutment with the house wall behind. Lead covers all of these, and each is detailed in its own way.
That is why this kind of roof is priced and planned after a survey. The covering is only one part of the job. The condition of the timber below, the way the old lead was fixed, the falls and the junction with the wall all change the scope of a repair or a renewal, and none of that can be read from a drawing or a photograph taken at ground level.
The lead roofing and leadwork page covers the wider range of jobs, from chimney flashings to valleys. This guide stays with bays and porches.
The parts of a lead bay roof
Every part of a lead bay roof has a name, and knowing the names makes a quote or a survey easier to follow. The table sets them out in the order water meets them, starting at the wall and ending at the gutter.
| Part | What it does |
|---|---|
| Abutment flashing | Seals the lead to the house wall |
| Main sheet | Covers the top of the bay |
| Rolls and drips | Join sheets and carry water down |
| Cheeks | Cover the angled sides |
| Front edge | Turns water into the gutter |
Underneath all of that is a deck of timber boards or ply, laid to the fall that the roof needs. The lead sits on an underlay that lets the sheet move without catching on the boards. A bay roof that leaks may have a lead covering in good order and a deck that has rotted below it, so the survey looks at what supports the lead as well as at the lead itself.
The names on a quote can vary from firm to firm, but the parts are the same. If a quote talks about renewing the "lead to the bay", it is worth asking whether that covers the abutment flashing and the front edge as well as the main sheet.
Why lead is used on bays and porches
A bay roof has corners where flat and sloping surfaces meet, and a porch can have the same. A rigid material needs a joint at every corner, and any joint is a seam that has to hold. Lead sheet is soft, and a roofer can dress it into an angle with hand tools, so one piece can run round a corner where another material would need two.
Lead also suits small areas. A bay roof may measure no more than a couple of square metres, and cutting a small roof out of a roll of membrane or boards of another material can be as much work as dressing lead. The metal is cut to fit, folded to the shape of the roof and fixed so that it can move with temperature.
Lead sheet is made in codes 3 to 8 to BS EN 12588, and the thickness rises with the code: code 4, for example, is 1.80 mm. Which code goes where is written into the specification, and a bay can call for one code on its main sheet and another on its flashing. The lead sheet codes guide gives the thickness of every code from 3 to 8, with weights from Calder and Ecobat where the maker is named.
Other materials are used on bays too, among them GRP, EPDM and zinc, and a house may have a different covering on its bay than elsewhere on the roof. Lead is not the only option, and the choice is made after the survey, on the details of that roof.
Falls, drainage and what BS 6229 does not cover
A bay roof is small, and it can be shallow. That brings a drainage question, because water that cannot run off will stand on the lead, find a seam and work its way into the timber. The covering has to be laid to a fall, towards a gutter at the front or to a hopper and downpipe at the side.
The current edition of the flat roof code of practice is BS 6229:2025. Its subject is the flat roof, or a curved one with a pitch not greater than 10 degrees, where the waterproof covering is a continuously supported flexible one. Those are membranes. Lead sheet falls outside that code, so its figures do not set a rule for a lead bay roof, even though a bay roof can be as flat as a garage. NFRC reports that BS 6229:2025 sets a minimum 1:80 finished fall for general roof areas and internal gutters; it is a figure for membrane roofs.
For lead, the fall comes from the specification for the job. The roofer works out the fall that the deck will give, the lengths of the sheets and where the joints go, and those are set out before the lead is cut. A lead bay roof that holds a puddle after rain has a drainage fault to look at, whether the cause is a deck that has sagged, a blocked outlet or a fall that was never enough.
The gutter needs as much attention as the covering. A blocked gutter below a bay roof can back up under the front edge and soak the timber, and a leak that appears inside the bay window may begin at the gutter. The survey therefore takes in the gutter, the outlet and the front edge together with the lead.
Where bay roofs leak
A leak from a bay roof shows up in two places: on the ceiling or wall above the bay window inside, and on the timber and plaster around the window head. The cause is on the roof, and it is found at one of a handful of details. The list runs from the wall to the front edge.
- The abutment flashing, where the lead meets the house wall and where the pointing above it has crumbled or the lead has lifted.
- Cracks at the folds of the cheeks and corners, where the sheet was bent tightly or has moved.
- Rolls and drips that have split or opened, so water passes under them.
- Holes or dents where something has fallen or been walked on.
- A front edge that no longer turns water into the gutter.
- A gutter or outlet that is blocked or leaking.
Lead does not always wear out evenly. A bay roof can have one detail that has failed while the sheet beside it is sound, which is why a repair to a single detail is sometimes possible. The repair or replace guide sets out how that choice is made, and the same reasoning carries over from flashings to a bay.
Damp inside a bay window can also come from other sources, such as condensation, a failed window seal, a leaking gutter or a hole in the wall above. Looking at the roof is one step, and the survey reads the whole bay.
Porch roofs and canopies
Three forms are possible: a small pitched porch roof with tiles or slates, a flat roof, or a canopy over a front door. Lead appears in several places. On a pitched porch, it forms the flashing where the porch roof joins the house wall, the valleys where the porch roof meets the main roof, and sometimes a lead roll over the ridge. On a flat porch, the lead may be the whole covering, in the same way as on a bay.
The abutment with the house wall is the detail to watch. A porch joins the main wall in one line, and a flashing there has to be tucked into the wall and lapped over the porch covering. If the porch was built after the house, the joint between the two may have been made with whatever suited the builder, and cement or sealant is not a flashing.
Porches and canopies are small, with few fixings between them and the wall. A canopy fixed to the wall with brackets can pull away and open the joint above it, and a porch roof that has settled can leave a gap at the abutment. A roofer looking at the porch checks the wall fixing, the flashing and the covering together.
A porch built under a flat roof needs the same attention to falls and outlets as a bay does, and the BS 6229 point applies in the same way: the standard covers membranes, so a lead porch roof follows its own specification.
Surveying and pricing a bay or porch
A bay or porch is priced after a survey. The MyJobQuote leadwork figures cover chimneys only, so they say nothing about a bay, a porch or any other lead roof. The price of a bay job follows from how big the roof is, how it is reached, the condition of the deck, the lead code specified and the number of details that need renewing.
| Item | Why it matters |
|---|---|
| Deck | A rotted board cannot hold lead flat |
| Fall | Standing water tests every seam |
| Abutment | The wall joint is open to the weather |
| Gutter | A blocked outlet backs water up |
The survey comes first, and the whole job is then quoted as a single written total. Where a bay or porch needs scaffold for safe access, the scaffold sits inside that written total, and we arrange the licence with our scaffolder. The leadwork costs guide goes through what drives the price on lead jobs across the whole house.
If you have a bay or porch that is leaking, take a photograph of the roof edge, the ceiling stain and the gutter below, and send it on WhatsApp to 07880 284133 or write to info@daylightroofingdunstable.co.uk. A photograph of the stain from inside is useful as well, because it shows where the water arrives. You can also call 01582 935272.