Call 01582 935272

Lead roofing

What code of lead is used for flashing?

No one code covers every flashing. Each detail takes the code its job specification gives it, and the codes run from 3 to 8.

Get a written quote

Call 01582 935272WhatsApp us

Lead roll roof on a bay window of a Victorian villa
PicturedLead roll roof on a bay window of a Victorian villa.

The short answer

The specification sets the code for each flashing, so no single code suits every detail. Codes 3 to 8 are made to BS EN 12588 as rolled lead sheet, from 1.32 mm thick for code 3 to 3.55 mm for code 8. Code 4 is 1.80 mm thick and code 5 is 2.24 mm.

A roof drawing with its parts named: lead valley, tiles, hipLead valleyTilesHip

Who chooses the code, and how

A lead code stands for a thickness of rolled sheet. The codes run from 3 to 8, the sheet is made to BS EN 12588, and a higher number means thicker lead. The code is not tied to a type of roof or a type of house. It is picked for each detail on the roof, and the choice is written into the specification for the job. Whoever drew up that document, whether a surveyor or the roofer, has already weighed how the lead will be bent, fixed and exposed.

A chimney apron, a stepped flashing up a gable wall, a valley and a bay roof are different details, and each can be given its own code, so one roof may carry more than one. The manufacturers' weight charts do not assign a code to any of them, and a claim that one code is the standard choice cannot be backed from those charts. The straightforward step is to ask what the specification says for the roof in question.

The lead sheet codes explained guide covers the system in more depth, and the lead roofing page lists the places on a roof where lead is used.

Codes 3 to 8 side by side

Each code has one thickness, whichever manufacturer rolled the sheet. Weight per square metre is a different matter, because each maker prints its own figures. The table gives those published by Calder and Ecobat, and it shows where they part company.

Rolled lead sheet to BS EN 12588, thickness and published weights
CodeThicknessCalder kg/m²Ecobat kg/m²
31.32 mm14.9715.0
41.80 mm20.4120.41
52.24 mm25.4025.40
62.65 mm30.0530.10
73.15 mm35.7235.72
83.55 mm40.2640.26

Codes 3 and 6 are the two where the figures differ, by a small margin. For that reason a weight should always travel with the name of the maker it came from, and a bare number of kilograms is of little use. The same goes for any colour marking: markings differ and cannot stand in for reading the specification itself.

Thickness is the figure to compare between quotes, since it does not change with the supplier. A quote that gives a code is giving a thickness, even if it never writes the millimetres, and the table above turns one into the other. For example, code 4 is 1.80 mm, which is thinner than code 5 at 2.24 mm and thicker than code 3 at 1.32 mm.

What the code means for your quote

A quote for leadwork should say which code goes on which detail, or point to a specification that does. If it says only lead flashing, the thickness is left open, and two quotes that look the same may be offering different metal. Asking for the code per detail puts them on the same footing.

A thicker code does not by itself promise a longer life. MyJobQuote says: "When correctly installed, lead flashing can last for over 80 years (over 100 years for higher codes) with minimal maintenance." Even that is a statement about lead installed correctly, and no promise is made for the lead on any single house.

What we charge is one written total, given after a look at the roof, and the code for each detail is settled in the specification. That keeps the thickness on paper where it can be checked. If you hold a quote and want a view on the lead in it, a clear photograph of the flashing sent to 07880 284133 on WhatsApp is a fair first step. The code 4 lead and code 5 lead pages look at those two codes one at a time.

Which code, and why

01Is code 4 the standard lead for flashings?

That cannot be said. Code 4 is 1.80 mm thick and is one of six codes in the range, but each detail takes the code its specification gives it, and no weight chart ranks any code as the standard. Where a quote names code 4, that is a choice for that detail, so ask why it was chosen and what the other details on the roof are given.

02Does a higher code mean a better flashing?

A higher code means thicker sheet, and that is all the number itself tells you. Whether thicker lead suits a detail depends on how the lead is to be dressed and what the specification calls for. Thick sheet is harder to work into a tight corner, so a higher code is not always the right one. The code is matched to the detail, as the specification does.

03Why do two makers show different weights for the same code?

Each maker publishes its own chart, and for codes 3 and 6 the figures differ slightly: 14.97 kg/m² from Calder and 15.0 from Ecobat for code 3, and 30.05 against 30.10 for code 6. For codes 4, 5, 7 and 8 the two agree. The thickness of each code is unchanged, which is why thickness is the safer figure to compare.

04How can I find out what code my existing flashing is?

From the ground it cannot be read, because the code is a thickness and the edge of the lead is hard to see. At a survey, the lead can be measured where it is exposed. A close photograph of an edge, with a coin laid next to it to show the size, is a useful starting point, and you can message it to 07880 284133 on WhatsApp ahead of a visit.

Get a written price for your roof

10-year workmanship guarantee, in writing

Tell us about your roof

Call WhatsApp Written quote