Call 01582 935272

Lead codes

Lead sheet codes 3 to 8 explained

A lead sheet code is a number that stands for thickness, from code 3 to code 8. This guide gives the thickness of each code, the weights two makers publish and how to read a code when it appears on a quote.

9 minute read

Get a written quote

Call 01582 935272WhatsApp us

A valley between two concrete tile slopes with a dry valley trough
PicturedA valley between two concrete tile slopes with a dry valley trough.
A roof drawing with its parts named: lead valley, tiles, hipLead valleyTilesHip

What a lead code is

Each rolled lead sheet carries a code from 3 to 8, and every code stands for one thickness. A higher number means a thicker sheet. On the charts of Calder and Ecobat, each headed 'Rolled Lead Sheet to BS EN 12588', a code carries the same thickness, so code 4 is 1.80 mm from either maker.

The code gives a clean way to talk about lead: a quote that says code 4 is naming a thickness of 1.80 mm, and any reader can check that against the table in this guide. Nobody needs to carry the numbers in their head, since the whole range fits in one short table.

A code on its own does not say where on the roof the lead is going. The same sheet can be cut into a flashing, a valley lining or a bay covering, and the specification for the job says which code goes into which detail. The codes themselves come first here; the other lead pages carry the details.

The lead roofing and leadwork page sets out the jobs that use lead sheet, and each code has a thickness, a weight, a place in the specification, a published lifespan and a line in the quote. Any one code can be looked up on its own, and the code tables can be held up against the codes named in a quote.

Thickness of codes 3 to 8

Thickness is the figure that does not change from one maker to another. The table gives it for every code in the range. Each step up the scale adds a fraction of a millimetre, so the difference between neighbouring codes is small, and the difference between code 3 and code 8 is a little over two millimetres.

Lead sheet codes to BS EN 12588: thickness
CodeThickness
31.32 mm
41.80 mm
52.24 mm
62.65 mm
73.15 mm
83.55 mm

The steps are not equal. Code 3 to code 4 adds 0.48 mm, code 4 to code 5 adds 0.44 mm, and code 5 to code 6 adds 0.41 mm. From code 6 to code 7 the step is 0.50 mm, and from code 7 to code 8 it is 0.40 mm. A reader comparing codes should look at the millimetres in the table rather than assume the numbers rise evenly.

Thickness is what a roofer works with, and it is also what a reader can check. Which code suits a detail is a question for the specification written for the roof, and no table of thicknesses can answer it. The table says what each code is, and the roof's own details say where each one goes.

Weights from Calder and Ecobat

Weight per m² is the other figure published for each code, and here the makers differ slightly. Calder Lead and Ecobat both publish charts headed "Rolled Lead Sheet to BS EN 12588". Their figures match for codes 4, 5, 7 and 8, but they differ for codes 3 and 6, so a weight is meaningful only with the maker named beside it.

Weight in kg per m² by maker
CodeCalderEcobat
314.9715.0
420.4120.41
525.4025.40
630.0530.10
735.7235.72
840.2640.26

The gaps are small: 0.03 kg per m² at code 3 and 0.05 kg at code 6. Even so, the figures are not interchangeable, and a weight quoted without a maker is not the same as a weight read off one chart. So read any weight with its maker's name beside it.

Weight per m² is a property of the sheet. It says nothing about how heavy a finished roof detail is, because a flashing is a narrow strip and a valley a long one, and the area of lead in each is what counts. Those weights describe lead alone, code by code, and set no lead roof against a covering of any other material.

The specification names the code

No code is right everywhere on a roof. A quote that says "code 4 lead" records one decision made for that job, and the code for each detail is written into the specification that goes with it. A chimney flashing, a valley and a bay roof can each take a different code, and the same house can carry more than one.

The makers' charts are weights and thicknesses, not a rule of the form "use code 4 here and code 5 there". What the charts allow is a clear statement of what each code is, and the choice for a roof is then made from its own details.

The specification is also the document a quote should follow. If a quote names a code for each part of the job, the reader can see what is being fitted. If it names none, the question to ask is which code is going where, since the code decides how much metal goes on the roof. A roofer should be able to answer that question in a sentence, and the answer should match the written quote.

For a reader who wants to see a single code in detail, the pages on code 4 lead and code 5 lead answer the question for each.

Codes and lifespan

MyJobQuote gives two figures for lead flashing. When it is correctly installed, it says, lead flashing can last for over 80 years, and it adds that the figure is over 100 years for higher codes, in both cases with minimal maintenance. That second figure ties lifespan to the higher codes in general, not to any one code.

The sentence needs reading carefully. "Higher codes" means the thicker sheets in the table, and "can last" stays with the figure: it describes what lead can do when it is installed properly, and it is neither a promise nor a lower limit. A thicker code does not rescue a flashing that was fixed badly, and a thinner one is not a defect where the specification calls for it.

Thickness is only one of the variables. The fixings, the laps, the pointing the top edge sits in and the movement allowed for in the lengths of sheet all affect how a flashing wears, and the guide on how long lead flashing lasts sets those out.

For flat roofs covered with lead, HomeBuilding gives 60 to 100 years and Less gives 50 to 100 years. Neither source ties its figure to a code, so no single code can be matched to either range. A roof's lead is judged by what the specification calls for and by how well it was installed.

You might hear

A higher lead code is always the better choice for a roof.

Plain as day

The code is named detail by detail in the specification, and thicker is not automatically right.

What lead codes do not tell you

A few things are sometimes assumed about lead codes, and none of them is supported by the makers' charts. A code does not carry a colour. A sheet's code is read from the maker's marking or from the order, and not from how the sheet looks.

A code also does not tell you the price of a job. A thicker sheet uses more metal, but the total depends on the length of lead, the access and the condition of what lies beneath, as the leadwork costs guide on this site explains. A code is a step on the way to a quote and not the quote itself.

Finally, a code is not a standard in its own right, and that is easy to forget when a quote uses the word loosely. BS EN 12588 is the standard rolled lead sheet is made to, and the codes are the thicknesses within it. Saying that a roof "meets code 4" is a statement about the sheet's thickness. It says nothing about how the sheet was laid, which is the other half of how long it lasts. A reader who hears that a roof was done "to code" should ask which code, which detail and which maker's sheet, because the phrase alone describes nothing.

The terms in this guide are short, and the panel sets them out in one place.

  • CodeA number from 3 to 8 that stands for sheet thickness
  • BS EN 12588The standard rolled lead sheet for building is made to
  • Rolled leadLead sheet made by rolling, supplied in coils or sheets
  • SpecificationThe document that names the code for each detail

Reading a code on a quote

When a quote names a code, the table in this guide turns it into millimetres. Code 4 is 1.80 mm, code 5 is 2.24 mm and so on. If the quote also gives a weight, look for the maker: Calder and Ecobat agree on most codes, but 14.97 and 15.0 are not the same figure for code 3, and the same goes for code 6.

A short checklist helps when reading any leadwork quote. Does it name a code for each part of the job? Does it say what happens to the pointing the lead sits in? Does it say whether boards or battens beneath are being repaired? A quote that answers these is describing real work, and one that answers none is describing a figure only.

Our quote follows a survey of the roof, comes as one written total price, and you are told plainly which code suits each part of the roof. If you have a quote from another firm and would like to understand it, a photograph of the page and of the roof sent on WhatsApp to 07880 284133 is a start, and you can also call 01582 935272.

The quote band at the foot of this page has the form, and email to info@daylightroofingdunstable.co.uk reaches the same people. A code on a quote is a good thing to ask about, because the answer shows how the job has been planned. Ask in plain words: which code, in which place, and why that one. A firm that has read the roof can answer all three.

Lead sheet codes, answered

01How thick is code 4 lead?

Code 4 lead is 1.80 mm thick. Rolled lead sheet is made to BS EN 12588 in codes 3 to 8, and the code is a number standing for thickness. Calder and Ecobat both give code 4 a weight of 20.41 kg per m². Their charts part company at codes 3 and 6, which is why a weight needs its maker named beside it.

02Do Calder and Ecobat give the same weights?

For codes 4, 5, 7 and 8 their charts match. They differ for code 3, where Calder gives 14.97 kg per m² and Ecobat 15.0, and for code 6, where Calder gives 30.05 and Ecobat 30.10. The gaps are tiny, but a weight should still be given with its maker named, and a thickness needs no maker at all because it is the same in every chart.

03Which lead code is used for flashings?

Each flashing takes the code its specification names, so no single code is right for every flashing. Rolled lead is made in codes 3 to 8, and one roof can carry more than one. A survey reads the details of the roof first, and the code each detail needs is then explained in plain words. No chart can pick a code for a roof it has not seen.

04Does a higher code mean lead lasts longer?

MyJobQuote gives over 100 years for higher codes, against "can last for over 80 years" for lead flashing, both when correctly installed and with minimal maintenance. That is a published pairing, and the wording carries its own qualifier, so a thicker sheet is no promise for any particular roof. How the lead was fixed and how it has been looked after count as well, and neither shows up in a table of codes.

05Are there colours for lead codes?

Codes do not come with a colour scheme: a sheet's code comes from the order and the maker's marking, and nothing about its look gives it away. If you are unsure which code a quote means, ask the firm to state it in millimetres, and set the answer against the thickness table in this guide. The numbers should agree with the table row for row.

Get a written price for your roof

10-year workmanship guarantee, in writing

Tell us about your roof

Call WhatsApp Written quote