Can a roof window be a fire escape window?

A roof window can serve as an escape window if its opening meets the sizes in Approved Document B. The measurements, the 4.5 m storey limit and the checks are set out below.

Get a written quote

Call 01582 935272WhatsApp us

A large commercial single-ply roof with rooflights and plant
PicturedA large commercial single-ply roof with rooflights and plant.

The short answer

Yes, a roof window can act as an escape window when the openable part has an area of at least 0.33 m², measures at least 450 mm in height and in width, and has its bottom edge no more than 1100 mm above the floor. The window route suits storeys up to 4.5 m above ground.

A roof drawing with its parts named: slates, roof window, lead collarSlatesRoof windowLead collar

Three measurements a roof window must meet

Approved Document B, the fire safety guidance for dwellings, gives three measurements for an emergency escape window in paragraph 2.10. The openable area must reach a minimum of 0.33 m². The openable part must also be at least 450 mm high and at least 450 mm wide. Finally, the bottom of the openable area must sit no more than 1100 mm above the floor.

These are separate limits, and a unit has to satisfy each. A window with a large pane can still fall short if only a narrow strip opens, because the figures refer to the part that opens, not to the frame or the glass. Two minimums of 450 mm do not multiply out to the area either: 450 mm by 450 mm is about 0.2 m², so a unit that only just reaches both minimums still needs a bigger opening to meet the 0.33 m² figure.

Escape window measurements in AD B paragraph 2.10
MeasurementRequirement
Openable areaMinimum 0.33 m²
Openable heightMinimum 450 mm
Openable widthMinimum 450 mm
Bottom of openable areaMaximum 1100 mm above the floor

Under a sloping ceiling, the height of the unit's lower edge above the floor needs measuring in the room itself, since a unit fixed high in the slope can end up beyond 1100 mm.

Which storeys a window can serve

The window route has a height ceiling: the storey concerned may be up to 4.5 m above the ground, and no higher. When a loft conversion produces a storey above 4.5 m, para 2.5 offers two alternatives to the window. One is a protected stairway, a stair walled off with fire-resisting construction to a minimum of REI 30. The other is an alternative escape route, in which the top storey is cut off from the rest of the house by fire-resisting construction and leads to a separate final exit.

Para 2.23 gives open-plan layouts a different possibility: sprinklers fitted in the open-plan areas. The layout and the height of the new storey decide which option suits a house, so the loft plan comes first and the glazing follows.

A roof window can serve as the escape route for a loft room inside the height limit. Stairs, doors and fire-resisting construction belong to the whole design, not just the glazing, and building control looks at all of them together. Where a room sits near the 4.5 m limit, the height of the floor above the ground is worth confirming on site before the opening is designed.

Testing a unit against the figures

Measure the opening with the sash open, not the frame. Note the clear height and the clear width, then the height of the lower edge of the opening above the finished floor. Multiply the clear height by the clear width to get the area. Compare each result with the figures in paragraph 2.10. A pivot unit that swings on a central bar may leave two narrow gaps rather than one clear opening, so the gaps are measured, not the overall width.

Where the figures fall short, a different size, a different position in the slope or a different type of unit may be needed. The answer may instead lie in a protected route, so the choice is not made by the glazing alone.

A new or enlarged opening in a roof is a structural change, so ask building control before ordering a unit. That may be the council's own team or a registered building control approver. On completion the council's team issues a completion certificate, while a registered approver issues what the regulations call a final certificate. The energy side is covered in roof windows and building regulations, and whether roof windows need Building Regulations approval answers the approval question. The main skylights and roof windows page lists the surrounding work. A single written figure follows the survey.

Escape windows in the roof, answered

01Does every roof window meet the escape measurements?

No. The measurements apply to the part that opens, so a unit with a generous pane but a small opening can fail. Check the clear height, the clear width and the area against paragraph 2.10, and measure the lower edge above the floor in the room. Makers publish opening sizes for each model, which helps narrow the choice, though the check in the room is what counts.

02Can a roof window serve a storey above 4.5 m?

No. Above that height a window is not the escape route. Where a loft conversion produces a storey above 4.5 m, para 2.5 calls for a protected stairway or an alternative escape route, and para 2.23 allows sprinklers in open-plan areas as another option. Glazing on its own does not stand in for those arrangements, however large the unit is.

03Who checks escape arrangements in a loft conversion?

Building control does. That means the council's building control team or a registered building control approver, whichever is appointed for the job. Raise the loft plan, and the position of the window in it, before the unit is ordered, because moving an opening after the roof is cut is far harder than moving it on a drawing, and the sign-off looks at the finished result.

04Which version of Approved Document B are these paragraphs from?

The paragraph numbers come from Approved Document B Volume 1 as published for England, the 2019 edition incorporating 2020, 2022, 2025 and 2026 amendments. The amendments are folded into that edition, so there is no separate 2026 edition to look up. Check the current text before relying on any paragraph number, since numbering can move between versions. A copy of the page in use, with its date, is worth keeping on file.