The short answer
Code 5 lead is rolled lead sheet 2.24 mm thick, made to BS EN 12588. Both Calder's and Ecobat's weight charts list it at 25.40 kg per square metre. It sits between code 4 at 1.80 mm and code 6 at 2.65 mm, and the specification for each job names the code for each detail.
The figures behind code 5
Code 5 is one step up from code 4 in the set of thickness classes defined in BS EN 12588, which runs from code 3 to code 8. The standard sets the thickness for each code, and code 5 is 2.24 mm. Each maker then publishes the mass of a square metre of sheet at that thickness.
- Thickness: 2.24 mm.
- Calder's weight chart: 25.40 kg per square metre.
- Ecobat's weight chart: 25.40 kg per square metre.
The two makers print the same weight for this code, so a figure quoted for code 5 does not depend on which of the two charts it came from. The comparison does not extend to every code, because codes 3 and 6 differ between them, and a weight from any other maker should be read off that maker's own chart.
A weight per square metre belongs to the sheet, not to a roof, and it is not the same as a total for the job. The lead on a particular job weighs whatever its total area comes to at that rate. Working that out needs the drawn areas from the specification and a survey, and the lead roofing hub explains the details those areas are made up of.
Code 5 in the full range of codes
Set against the codes above it, code 5 is the lightest of the four in the table. The table gives the four codes from 5 to 8 with both makers' weights.
| Code | Thickness | Calder | Ecobat |
|---|---|---|---|
| 5 | 2.24 mm | 25.40 kg/m2 | 25.40 kg/m2 |
| 6 | 2.65 mm | 30.05 kg/m2 | 30.10 kg/m2 |
| 7 | 3.15 mm | 35.72 kg/m2 | 35.72 kg/m2 |
| 8 | 3.55 mm | 40.26 kg/m2 | 40.26 kg/m2 |
Each step up the table adds between 0.40 and 0.50 mm of thickness, so the thicknesses climb in fairly even stages while the weights climb by roughly five kilograms per square metre. Code 5 is 0.44 mm thicker than the code below it, which is covered in what is code 4 lead, and 0.41 mm thinner than code 6. Of the four codes in the table, only code 6 gets a different weight from each maker, 30.05 from Calder against 30.10 from Ecobat.
The table is a reference for sizes only, and it is not a guide to which detail takes which code. The lead sheet codes guide takes the whole range in order.
Reading a quote that names code 5
A written quote or specification that names code 5 is naming a thickness, 2.24 mm. It is worth checking that the code and the detail it is attached to are both written down, since the specification sets the code for each part of the roof separately. A quote that names code 5 for one flashing says nothing about the code on the next.
Thickness is not the only thing a quote should make clear, but it is the one that can be checked later, because lead is a metal with a measurable gauge. If the lead on the roof has been in place for some time, an exposed edge can be measured with callipers during a survey, which gives a check against any paperwork that survives. Where the paperwork and the measurement disagree, the measurement is the fact to work from.
On durability, MyJobQuote says that when correctly installed, lead flashing can last for over 80 years (over 100 years for higher codes) with minimal maintenance. It does not say which codes count as higher, so no lifespan for code 5 follows from it. Whether lead is patched or renewed follows from its state, and the page on repair or replace lead flashing goes through that decision.