The short answer
Code 4 lead is rolled lead sheet 1.80 mm thick, made to BS EN 12588. Calder's weight chart gives it 20.41 kg per square metre and Ecobat's chart gives the same figure. It is one of six codes, from 3 to 8, and each job's specification decides which code goes on each detail.
What the code 4 label stands for
Lead for roofs is bought as rolled sheet, which comes in numbered thickness classes called codes. They are defined in BS EN 12588, which covers rolled lead sheet for building, and the codes run from 3 to 8. A higher number means thicker metal. Code 4 is 1.80 mm thick.
The weight on a chart is a different measure from the thickness, though the two move together. Each maker publishes a weight chart giving the mass of lead per square metre of sheet for every code. Calder's chart gives code 4 as 20.41 kg per square metre, and Ecobat's chart gives 20.41 as well. Both figures are for rolled lead sheet to the same standard, so for code 4 the makers agree.
The numbers are per square metre, so they do not describe a whole sheet or a whole roof. A strip of lead with an area of half a square metre carries half the figure. What a given roof's leadwork weighs in all depends on its area, which the specification and the survey establish, and a printed code gives no total on its own. The lead roofing hub covers where this sheet is used.
Code 4 against the codes beside it
The makers do not agree on every code, which is why a weight is always given with the maker's name. The table shows code 4 with the codes on either side.
| Code | Thickness | Calder | Ecobat |
|---|---|---|---|
| 3 | 1.32 mm | 14.97 kg/m2 | 15.0 kg/m2 |
| 4 | 1.80 mm | 20.41 kg/m2 | 20.41 kg/m2 |
| 5 | 2.24 mm | 25.40 kg/m2 | 25.40 kg/m2 |
Code 4 is 0.48 mm thicker than code 3 and 0.44 mm thinner than code 5. The next code up is covered in what is code 5 lead. On Calder's chart the step from code 3 to code 4 is 5.44 kg per square metre, and from code 4 to code 5 it is 4.99. Codes 3 and 6 are the two where the makers' weights differ, and by a small amount: Calder gives 14.97 for code 3 where Ecobat gives 15.0.
A thickness of 1.80 mm says nothing, by itself, about how long a piece of leadwork will last. MyJobQuote says correctly installed lead flashing can last for over 80 years, and adds a higher figure for higher codes, and that is its statement about flashing, not a lifespan for code 4.
Who chooses the code for a roof
Every detail on a job gets its code from the specification. A drawing or a written specification may name one code for a valley lining and another for a flashing, and the choice reflects the detail, not a rule that applies to every roof. Thickness changes how the metal behaves in the hand: a thicker sheet resists being bent tightly round a corner and weighs more on the way up a ladder, while a thinner sheet shapes more easily and can move more readily where it is poorly fixed. Those are reasons a specifier weighs, and they differ from one junction to the next.
When an existing roof carries code 4, the thickness of the lead already there is a fact a survey can record, and a repair is judged against what its own specification calls for. For a new job, the code can be named in the written quote, so you can see what thickness is being priced and compare it with the specification. If the quote names no code at all, that is worth asking about before any work is agreed.
The question of which code goes on which detail is worked through in what code lead is used for flashing, and the wider set of codes is laid out in lead sheet codes explained.