The short answer
On Calder's chart, rolled lead sheet weighs between 14.97 and 40.26 kg per square metre, by code. Code 4, at 1.80 mm thick, is 20.41 kg on both Calder's and Ecobat's charts. The two makers differ at codes 3 and 6, so a weight is only given alongside the name of the maker.
The weight chart for codes 3 to 8
Sheet lead for roofs is made to BS EN 12588 in codes 3 to 8, and each code is a thickness. Each maker then prints the mass of a one-metre square of sheet cut at that thickness, in kilograms. Both makers head their charts as rolled lead sheet to the standard. The table sets out the thickness and both makers' figures, as printed on Calder's and Ecobat's weight charts.
| Code | Thickness | Calder | Ecobat |
|---|---|---|---|
| 3 | 1.32 mm | 14.97 kg | 15.0 kg |
| 4 | 1.80 mm | 20.41 kg | 20.41 kg |
| 5 | 2.24 mm | 25.40 kg | 25.40 kg |
| 6 | 2.65 mm | 30.05 kg | 30.10 kg |
| 7 | 3.15 mm | 35.72 kg | 35.72 kg |
| 8 | 3.55 mm | 40.26 kg | 40.26 kg |
Every figure is for one square metre, so it describes the sheet and not a finished roof, and the amount of lead on a roof depends on its area. The weight rises in step with the thickness: on Calder's chart, code 8 is about 2.7 times the weight of code 3, and 3.55 mm is about 2.7 times 1.32 mm. The lead roofing hub explains where the different thicknesses are put to use.
Where Calder and Ecobat differ
Four of the six codes carry the same weight on both charts, and two do not. The differences are small, but they are the reason a weight is never quoted without the name of its maker.
- Code 3: Calder gives 14.97 kg, Ecobat gives 15.0 kg.
- Code 6: Calder gives 30.05 kg, Ecobat gives 30.10 kg.
For codes 4, 5, 7 and 8 the two charts match to the hundredth of a kilogram. When reading any chart, check three things: the standard in its heading, the maker's name and the unit, which is kilograms per square metre. A weight from a third maker is not covered by either chart, and it should be read from that maker's own chart. If a quote or a specification gives a weight, ask which maker's chart it was taken from, since a figure with no maker named cannot be checked.
Thickness is the steadier figure to work from, because the standard fixes it for each code and no maker varies it. The guide to lead sheet codes explained covers the thickness side in more detail.
Turning a weight per square metre into a piece
A figure per square metre becomes the weight of a piece by multiplying it by the piece's area. A strip of code 5 lead covering half a square metre weighs half of 25.40 kg on either chart, which is 12.70 kg. A piece of code 4 of 2 square metres weighs 40.82 kg on Calder's chart, or on Ecobat's.
The arithmetic is for sheet weight only, and the figure it gives is the mass of lead sheet, which is a separate matter from the load a roof structure carries. It gives what a piece of lead weighs; it cannot give what a job will cost, how many pieces a roof needs or which code belongs on which detail. The specification decides the last of these, and the page on what is code 4 lead works through one code in full.
Weight on the chart is not a measure of how long the lead will last. MyJobQuote says that correctly installed lead flashing can last for over 80 years, and over 100 years for higher codes. The statement is about flashing and leaves out which codes it counts as higher, so a weight chart cannot be read as a lifespan table. A quote with both the code and the maker written on it lets the sheet that arrives be checked against the chart.