The short answer
Roofing underlay is a sheet stretched across the rafters, hidden under the battens and tiles, that acts as a second barrier against wind-driven rain, snow and dust. It comes as traditional felt or as modern membrane. High-resistance sheet stops vapour passing, while the low-resistance kind lets it pass, and that choice affects ventilation.
What underlay is for
Tiles and slates overlap each other to shed rain, but they do not form a sealed surface. Wind can push rain or snow up beneath them, and gaps open where a tile has cracked or slipped. The underlay is the layer below that catches such water and guides it down the slope, over the eaves and into the gutter. It is a safety net under the covering and is not the covering itself.
In build-up order, it lies across the rafters, with the battens fixed over it and the tiles hung from those. From outside it cannot be seen. From a loft it shows as the sheet between the rafters. Because it is hidden, nobody sees its condition until the covering is lifted or someone looks up from the hatch with a torch, and a leak can run for a while before anything shows below.
A sound underlay is whole, lapped properly at its joins and sealed where it meets other parts of the roof. A torn, perished or slipped sheet leaves a path for water to reach the roof timbers. The roof battens answer describes the laths that sit directly above it.
Felt, membrane and high or low resistance
- Traditional bitumen felt, which is a high-resistance (HR) underlay.
- Modern vapour-permeable membranes, which are low-resistance (LR) underlays and are sold as breathable.
- Rigid sarking boards in certain builds, a separate system not covered in this answer.
The word that matters here is resistance. A high-resistance sheet holds water vapour back. It lets none through, which is why it should never be described as breathable. A low-resistance sheet allows vapour to pass. The breathable roof membrane answer deals with that second type on its own.
The type fitted changes what the roof void needs. Marley, writing to BS 5250 (listed as current, under review), gives 25 mm of gap at the eaves for roofs pitched at 15° or under and 10 mm for steeper roofs, in a cold roof under HR underlay. A cold roof is one with insulation at ceiling level, so the void above stays cold and ventilated. A different, much smaller allowance applies to LR underlay where the ceiling and covering allow it.
Fit the wrong sheet, or block the openings at the eaves, and warm damp air can sit in the roof void with nowhere to go. That is why the underlay already on a roof is identified before a different one is chosen to go over the same rafters.
Replacing it and what it costs
Underlay gets renewed in a re-tile, since the old sheet is laid open once the tiles and battens are off. A sheet that is intact and well lapped may be judged fit to stay. One that is brittle, torn or sagging between the rafters comes out, and a new sheet is lapped into place before the battens return. The life quoted for a tile does not carry over to the sheet beneath, and underlay has no lifespan figure of its own that can be quoted.
Underlay does not have a price of its own that can be quoted. For scale, HomeBuilding, on a page last updated 30 September 2025, puts a three-bedroom semi with a 65m² roof, in plain concrete tiles, at a cost that may run between £10,000 and £15,000 to re-cover. Underlay is one part of a job at that size, and the figure is a source's range, not a price from us.
Daylight Roofing sends one total, in writing, once the survey is done, and a photo from the loft of the sheet under the tiles is welcome on 07880 284133 on WhatsApp. Stripping every slope and laying a fresh covering goes beyond the 50% limit and needs Building Regulations approval, covered in the re-tiling and building regulations guide. More is gathered under pitched roofing.